Time Synchronization User's Guide
HP NonStop Time Synchronization User’s Guide  Page 65 of 81 
1005 
1005: TimeSync shutting down 
TimeSync is shutting down normally. 
Cause. The operator or system initiated a shutdown of the TimeSync process. 
Effect.  TimeSync shuts down. 
Recovery. Not applicable. 
1006 
1006: Error initializing application socket: description 
TimeSync could not initialize an application socket. 
description 
is the description of the error condition encountered. 
Cause. TimeSync could not obtain a socket from the communication infrastructure. 
Effect.  TimeSync shuts down. 
Recovery. Check the system log and/or TimeSync log for additional messages detailing 
the specific cause of the error. Check to be sure that all network infrastructure is up and 
running (network device drivers, TCP/IP processes/daemons, etc.), and ensure that 
TimeSync is not configured to use a LocalPort that is currently being used by a different 
application. 
1007 
1007: Select error on application socket, error number errnum 
TimeSync could not perform a select operation on an application socket (OSS, Linux, and 
Windows only). 
errnum 
is the specific error number returned by the sockets interface layer. 
Cause. An internal error in the sockets infrastructure. 
Effect.  TimeSync delays and then retries the operation. 
Recovery. Check the system log and/or TimeSync log for additional messages. Check to 