Time Synchronization User's Guide
HP NonStop Time Synchronization User’s Guide  Page 79 of 81 
7.4  OSS-specific Messages 
This section describes messages that are logged only on NonStop systems running the 
OSS version of TimeSync. These messages will not be logged on any other platform. 
4000 
4000: Error obtaining system time; could not proceed with time update 
TimeSync could not obtain the local system time while preparing to update the time. 
Cause. TimeSync could not retrieve the current local system time while preparing to 
perform a clock update. In most cases, this is a security-related issue. 
Effect. TimeSync does not adjust the local system time. 
Recovery. Verify that TimeSync is running with SUPER group permissions. 
4001 
4001: Error updating system time; could not proceed with time update - 
ensure that TimeSync is running with SUPER group authority 
TimeSync could not set the local system time. 
Cause. TimeSync could not set the local system time. In most cases, this is a security-
related issue. 
Effect. TimeSync does not set the local system time. 
Recovery. Verify that TimeSync is running with SUPER group permissions. 