TMF Application Programmer's Guide (G06.26+)
File System Procedures
HP NonStop TMF Application Programmer’s Guide—522419-005
4-9
COMPUTETRANSID
transid output
FIXED .EXT:ref:1 or INT .EXT:ref:4
is the internal name of the transaction identifier.
system input
INT(32):value
is a required system number in the range 0 through 254.
cpu input
INT:value
is a required CPU number in the range 0 through 15.
sequence input
INT(32):value
is a required sequence number greater than 0.
tm-flags input
INT:value
is a number representing flags used internally by TMF.