TN3270 Server Manual
TN32COM Error Messages
TN3270 Server Manual—424097-001
C-11
Error Messages
42
Cause. An error occurred during a WRITEREAD request to the Guardian TN3270
Server process, where err specifies the NonStop operating system file system error.
Effect. The command did not execute and the trace process was not started.
Recovery. Resolve the error condition as described in the Guardian Procedure Errors
and Messages Manual and then reenter the command.
43
Cause. An unsigned decimal integer entered on the command line was greater than
65535 or in error.
Effect. The command did not execute.
Recovery. Check the input for accuracy of the integer. If necessary, enter HELP and the
command name to get information about the rules for integer values. Finally, retry the
command.
44
Cause. An invalid port number was entered on the command line.
Effect. The command did not execute.
Recovery. Check the input for accuracy of the port number. If necessary, enter HELP
and the command name to get information about the rules for port number values.
Finally, retry the command.
45
Cause. The specified Guardian TN3270 Server process could not be found.
Effect. The command did not execute.
Recovery. Ensure that the process you are trying to open can be executed by
TN32SERV and then reenter the command.
Writeread error: err
Integer too large
Illegal port number
Process not found: process-name