TN3270e Server Manual

ETN32COM Error Messages
TN3270e Server Manual422923-003
C-3
Error Messages
8
Cause. The TN3270e server process name was invalid.
Effect. The command did not execute and the TN3270e server did not start.
Recovery. Ensure that the process you are trying to open is executable by
ETN32SRV and then reenter the command.
9
Cause. A process was opened that returned an incorrect subsystem ID (SSID).
Effect. The command did not execute.
Recovery. Ensure that the process you are trying to open is executable by
ETN32SRV and then reenter the command.
10
Cause. A NonStop OS file system error was encountered while opening a TN3270e
server process, where err specifies the error.
Effect. The command did not execute and the TN3270e server did not start.
Recovery. Resolve the error condition as described in the Guardian Procedure Errors
and Messages Manual and then reenter the command.
11
Cause. When opening a TN3270e server process, the process name contained a
qualifier. ETN32COM automatically adds the #ZSPI qualifier.
Effect. The command did not execute and the TN3270e server did not start.
Recovery. Reenter the command without the qualifier.
Process is not ETN32SRV
SSID is not ETN32SRV
Open error err
Process name must not be qualified