Token-Ring Adapter Installation and Support Guide
Introduction to the Token-Ring SeverNet Adapter
(TRSA)
Token-Ring Adapter Installation and Support Guide—426955-001
1-9
Manufacturing Naming Conventions
Manufacturing Naming Conventions
Compaq manufacturing uses a naming convention for processes and devices that relates
logical names to the physical location of devices. Table 1-1 describes the naming
conventions used for SLSA subsystem processes and other processes and devices
required by the SLSA subsystem.
cabid
is the two-digit number that identifies the enclosure; cabid is also the group
number.
slot
is the physical slot number in the enclosure for the TRSA.
portid
is the combination of the slot number and port number for the TRSA. The port
number for the TRSA is always 0; thus, the portid is mapped in the following way:
Table 1-1. Naming Convention for LAN Subsystem and Related Processes
Process or Device Type Convention Example
LAN Manager (LANMAN)
process
Must be $ZZLAN $ZZLAN
Logical interface (LIF) $ZZLAN.Lcabid-portid $ZZLAN.L018
Token-Ring ServerNet
adapter (TRSA)
$ZZLAN.Ecabid-slot $ZZLAN.E0153
cabid Description Range of Values
0n The object is in processor enclosure n. 01-08
n1 The object is in I/O enclosure 1 attached
to processor enclosure n.
11, 21, 31, 41, 51, 61, 71, or
81
n2 The object is in I/O enclosure 2 attached
to processor enclosure n.
12, 22, 32, 42, 52, 62, 72, or
82
n3 The object is in I/O enclosure 3 attached
to processor enclosure n.
13, 23, 33, 43, 53, 63, 73, or
83
Number Enclosure
53 to 54 processor enclosure
51 to 54 I/O enclosure