Token-Ring Adapter Installation and Support Guide
Token-Ring Adapter Installation and Support Guide—426955-001
3-1
3
Replacing a TRSA
This procedure section describes how to perform online replacement of a Token-Ring
ServerNet adapter (TRSA) in a Compaq NonStop™ Himalaya S-series server. You
might need to replace the TRSA if it has failed or partially failed. If POST fails and if
there is an alarm generated by the TSM package on the SAC TRSA, the TRSA must be
replaced.
Removal and replacement of the TRSA is described in the following subsections:
Note. A TRSA can be installed without shutting down the system.
Caution. If a previously installed TRSA and backplane connector have damaged pins, remove
the TRSA and install a filler panel in the vacant slot. Attach red tags to the filler panel to identify
the slot. Do not move the damaged TRSA to a different, undamaged slot. Both the TRSA and
backplane (or enclosure) must be replaced. For backplane replacement, refer to the backplane
replacement section of the Himalaya S-Series Service Provider Supplement available in
G-series Total Information Manager (TIM) collections.
Prepare to Replace a TRSA Page 3-2
Replace the TRSA Page 3-15
Resume Operations Page 3-25
Note. Whenever you handle the TRSA, you should follow standard operating practices to
avoid damage to the equipment. See Review Standard Operating Practices on page 3-15.