Token-Ring Adapter Installation and Support Guide

Replacing a TRSA
Token-Ring Adapter Installation and Support Guide426955-001
3-2
Prepare to Replace a TRSA
Prepare to Replace a TRSA
TRSAs can be installed in slots 53 and 54 of a processor enclosure and in slots 51, 52,
53, and 54 of an I/O enclosure. See Figure 3-2 on page 3-14. When no TRSA is installed
in a slot, a ServerNet adapter filler panel occupies the empty slot. (Therefore, a
ServerNet adapter filler panel might occupy slots 53 and 54 of a processor enclosure or
slots 51 through 54 of an I/O enclosure.) The filler panel maintains proper air flow and
reduces electromagnetic interference (EMI).
Table 3-1
summarizes the important steps for preparing to replace a TRSA.
Gather the Proper Tools
You will need the following tools to replace an adapter:
Table 3-1. Preparation Checklist
Step Description Comments
1.
Gather the Proper Tools
2.
Print the TRSA Planning Worksheet See Figure 3-1 on
page 3-3.
3.
Identify Any Communications Lines Using the TRSA
4. Redirect or Stop Any Customer Applications Using the
TRSA
5. Determine the Physical Location of the TRSA
6. Abort the TRSA
7. Stop the Communications Lines Using the TRSA
8. Label the Communications Cable Connected to the TRSA
Tool Used to. . .
Electrostatic discharge (ESD)
wriststrap with grounding clip
Protect the adapter from damage caused by electrostatic
discharge.
Antistatic mat (recommended) Provide a static-free environment for removal and
installation of an adapter.
Flashlight Check the connectors for bent or broken pins.
Note. An ESD protection kit can be purchased from Compaq using the following order number
and part number:
Order Number: ESD-Kit
Part Number: T99247-A00