Token-Ring Adapter Installation and Support Guide
Replacing a TRSA
Token-Ring Adapter Installation and Support Guide—426955-001
3-17
Remove the Adapter
Remove the Adapter
The following steps describe how to remove the adapter:
1. Disconnect the communications cables from the TRSA.
2. Put on your electrostatic discharge (ESD) wriststrap and connect the grounding clip
securely to an exposed, unpainted, metal surface on the service side of the system
enclosure, such as the processor multifunction (PMF) adapter or I/O multifunction
(IOMF) adapter ventilation holes
Figure 3-4
on page 3-17 shows how to connect the grounding clip to the ventilation
holes on the PMF adapter or IOMF adapter.
3. Unlatch the ejector on the TRSA by pressing the blue-green tab on the ejector and
pulling the ejector outward to unseat the TRSA from the backplane.
4. Grasp the TRSA by its ejector in one hand and slowly pull the TRSA out of the slot
while supporting the bottom edge of the TRSA with the other hand.
Figure 3-5
shows how to pull the adapter out of the slot.
Figure 3-4. Grounding Clip
Note. The TRSA weighs 6.75 pounds (3 kilograms).
081CDT .CDD
Processor Multifunction (PMF) CRU or
I/O Multifunction (IOMF) CRU
Grounding
Clip
To Grounding
Wriststrap