Replacing a TRSA
Token-Ring Adapter Installation and Support Guide426955-001
3-28
Restart the Communications Lines
c. From the Resource type pull-down menu, select the resource type.
d. From the Display pull-down menu, select Down-rev only.
A list of resources whose firmware is older than the version of the SYSnn is
displayed in the Available list box. Do the following:
e. Double-click on the resource. The resource is displayed in the Selected list
box.Choose
f. Perform action to update the firmware.
Restart the Communications Lines
Perform the following commands to start the communications lines.
1. Start the TCP/IP subnet.
Use the SCF START SUBNET command:
START SUBNET $tcpip-process-name.#subnet-name
2. Start an IPXPROTO process.
Use the SCF START PROCESS command:
START PROCESS $process-name
3. Start a Port Access Method (PAM) line.
Use the SCF START LINE command with the SUB ALL option:
START LINE $line-name, SUB ALL
4. To start a SNAX/TR line, perform the following steps:
a. Start the WAN subsystem input/output process (IOP).
Use the SCF START DEVICE command:
START DEVICE $ZZWAN.#device-name
b. Start the SNAX/TR line.
Use the SCF START LINE command:
START LINE $line-name
Note. To start TCP/IP subnets that are configured using Parallel Library TCP/IP, refer to the