Token-Ring Adapter Installation and Support Guide
Relocating a TRSA
Token-Ring Adapter Installation and Support Guide—426955-001
4-22
Check the Installation of the Relocated TRSA
Check the Installation of the Relocated TRSA
1. Make sure that the power-on LED (green light) is on.
Figure 4-8
shows the location of the power-on LED and fault LED.
2. If the power-on LED (green light) does not come on, do one or both of the
following:
•
Reseat the TRSA.
•
Check the TRSA and backplane connector for damaged pins.
Note the Following Error Conditions
•
If the power-on LED does not come on after you reseat the TRSA, you must replace
the TRSA
•
If the TRSA or backplane connector have damaged pins, both the TRSA and
backplane (or enclosure) must be replaced. For backplane replacement instructions,
refer to the Himalaya S-Series Service Provider Supplement.
Note. When the adapter is inserted, the fault LED (yellow) remains on until the service
processor has completed its start-up configuration; the fault LED also turns on when a
POST failure is detected.