COMMANDS AND RESPONSES
LOAD Command
LOAD Command
The LOAD command causes the specified software to be downloaded
to the Communications Line Interface Processor (CLIP). You can
only specify the LINE object in the LOAD command.
When your management application issues the LOAD command, the
line must be in the STOPPED summary state and must not already
be loaded. Once the command is completed and the CLIP is loaded,
start the CLIP.
Typically, a RESET must be performed prior to issuing the LOAD
command. However, if the NOLOAD modifier has been specified at
system generation time, the line comes up not loaded, and the
subsystem can accept the LOAD command without previously being
RESET.
Command
ZCOM-CMD-LOAD
Object Type
ZCOM-OBJ-LINE
Tokens in Command Buffer
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING. !{}
ZCOM-MAP-REQID !MAP is optional, but if present,
!fields are required.
def ZCOM-DDL-REQID.
02 ZCRTPID type ZSPI-DDL-CRTPID.
02 ZPAID type ZSPI-DDL-INT.
end.
ZCOM-TKN-CMD-TIMEOUT token-type ZSPI-TYP-TIMESTAMP.
ZSPI-TKN-MANAGER token-type ZSPI-TYP-FNAME32.
ZSPI-TKN-SSID token-type ZSPI-TYP-SSID. !{}
ZSPI-TKN-MAXRESP token-type ZSPI-TYP-INT.
ZSPI-TKN-CONTEXT token-type ZSPI-TYP-BYTESTRING.
ZSPI-TKN-RESPONSE-TYPE token-type ZSPI-TYP-ENUM.
ZSPI-TKN-ALLOW-TYPE token-type ZSPI-TYP-ENUM.
ZSPI-TKN-COMMENT token-type ZSPI-TYP-STRING.
>