TR3271 Management Programming Manual

COMMANDS AND RESPONSES
START Command
START Command
The START command initiates the operation of lines and subde-
vices. When the subsystem completes processing this command, the
specified object is placed in the STARTED summary state. You can
start a line or a subdevice, but not a process.
When you are using the START command, the line must be in the
STOPPED summary state; it cannot be in the DIAGNOSING or the
STARTED summary state.
When your management application issues the START command for the
LINE object, the subsystem checks for the subordinate-modifier
token. If the SUB modifier is not present, only the line is
started. If the value of the modifier is ZCOM-VAL-SUB-ONLY, the
subdevices attached to the specified line are started; the line
must already be in the STARTED summary state. If the value of
the modifier is ZCOM-VAL-SUB-ALL, the subsystem starts the line
and then all the associated subdevices. If the value is ZCOM-
VAL-SUB-NONE, only the line is started. The value ZCOM-VAL-SUB-
NONE has the same effect as if the SUB modifier was not present
in the command buffer.
When your management application issues the START command for a
subdevice, the subsystem starts only the specified subdevice. If
the value of the SUB modifier is ZCOM-VAL-SUB-ONLY, the command
is rejected. If the value of the SUB modifier is ZCOM-VAL-
SUB-ALL or ZCOM-VAL-SUB-NONE, the subsystem starts the named
subdevice only.
Command
ZCOM-CMD-START
Object Type
ZCOM-OBJ-LINE
or
ZCOM-OBJ-SU
Tokens in Command Buffer
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING. !{}
ZCOM-MAP-REQID !MAP is optional, but if present,
!fields are required.
def ZCOM-DDL-REQID.
>
6-84