TRANSFER Installation and Management Guide

Example of Reconfiguring the Depot Statistics Facility
Using ADMIN to Administer TRANSFER
13198 Tandem Computers Incorporated 9–21
7. Do not change the Standard Item Counting default because counting only one
incidence of an item takes more system resources than you are willing to use.
8. Press F8 to update the values.
After you stop the TRANSFER system and bring it up again, the new configuration
takes effect.
Figure 9-6 illustrates the new configuration on the DEPOT STATISTICS
CONFIGURATION screen.
Figure 9-6. After Reconfiguring the Depot Statistics Facility
ADMIN Depot Statistics Configuration
Current Config Next Config
---------------- ---------------------
Collect Statistics: Y Y Y = Yes, N = No
Statistics Ready: Y
Count Items When Examined: Y Y Y = Yes, N = No
Units used are D = Day, H = Hour, and M = Minute:
Base Time: 00:00 0 : 00
Sample Interval: 7D 7 D (D/H/M)
Number of Samples (Per Average): 13 13
Number of Averages: 4 4
Standard Item Counting: Y Y
--------------------------------------------------------------------------------
F1 - Show config F8 - Update
SF14 - Recover F15 - Help F16 - Return SF16 - Main Menu
BLOCK