TRANSFER Installation and Management Guide

Gateway Startup Messages
Error Messages
13198 Tandem Computers Incorporated B–39
C2061 Internal inconsistency
Cause. An internal inconsistency was detected while attempting to open an MTA
process.
Effect. The server stops after generating this message.
Recovery. Report this error to the system analyst and restart the server.
C2062 Failed to delete unacceptable MTA queue entry
Cause. The MTA queue entry was no longer valid, but an attempt to delete it failed.
Effect. None; the server continues.
Recovery. No action is necessary; the server continue.s
C2064 Error
nnnn
getting system trigger character
Cause. The server had error nnnn when trying to get the system trigger character.
Effect. The server stops after generating this message.
Recovery. Determine why the system trigger character cannot be retrieved from the
namespace. Correct the problem and restart the server.
C2065 Error
nnnn
enqueueing MTA’s ADMIN QUEUE entry
Cause. The Exporter had error nnnn when trying to put an MTA queue entry back into
the queue.
Effect. The server continues. If, however, there are multiple Exporter server processes,
they might not be load-balanced across the available MTAs because they all see the
same MTA queue entry.
Recovery. Determine why error nnnn occurred and correct the problem.