TRANSFER Reference Manual
GET-PROFILE-ELEM Element Identifier 3
TISERV UOW Descriptions
069139, Update 1 to 40969 Tandem Computers Incorporated 2–333
DELIV-END-DELTA
is the default time period between initiation of delivery and latest permitted
delivery time.
EXPIRATION-DELTA
is the default time period between delivery end and the time when the package
expires.
The return code is defined as follows:
DEF rtn-depot-deltas TYPE BINARY 16.
RTN-DEPOT-DELTAS
is one of the following values:
0 OK
4072 E-UNITS-MUST-BE-DHM
4074 E-INVALID-REL-TIME-QTY
4238 E-TFER-PROFILE-ABSENT
4303 E-WINDOW-TOO-LARGE
Element Identifier 3
Element Identifier 3 accesses the default package priority for a depot.
DEF data-depot-priorities.
02 elem-identifier TYPE BINARY 16 VALUE 3.
02 dd-priorities-rtn TYPE BINARY 16.
02 default-priority PIC 9(3) COMP.
02 maximum-priority PIC 9(3) COMP.
02 filler TYPE CHARACTER 28 VALUE SPACES.
END.
ELEM-IDENTIFIER
is 3.
DD-PRIORITIES-RTN
is one of the following:
0 OK
4238 E-TFER-PROFILE-ABSENT
DEFAULT-PRIORITY
is the default priority assigned to packages submitted from the depot.