GET-STATS-PARAMS
TISERV UOW Descriptions
2–392 069139, Update 1 to 40969 Tandem Computers Incorporated
03 hour PIC 9(2).
03 minute PIC 9(2).
03 second PIC 9(2).
02 reserved TYPE CHARACTER 20 VALUE SPACES.
END.
HDR
is the UOW header. The UOW-CODE value is 273.
SELECT-CONFIG
allows access to the current, next, or previous configuration parameters. A value
of PREV-CONFIG returns the configuration that existed when TRANSFER
XCOOL completed.
RETN-CODE
is the return code. TISERV returns a code in this field to indicate one of the
following conditions:
0 OK
4093 E-SECURITY-VIOLATION
6120 E-DSF-NO-STATS-PARAMS
6131 E-DSF-NEXTCONFIG
6132 E-DSF-CURRCONFIG
6138 E-DSF-BAD-SELECT-CONFIG
RETN-CODE-DETAIL
is an error number returned by a subsystem other than the TRANSFER delivery
system or is a further qualification of an error detected by the TRANSFER delivery
system.
STATS-STATE
indicates the current state of the depot storage statistics facility.
STATS-STOP (0)
indicates that the depot storage statistics facility is not running. No statistics
are being calculated for folders or depots.
STATS-COLLECT (2)
indicates that the current and past depot storage statistics are available.
STATS-NOT-READY-C (4)
The depot storage statistics facility is not ready. Statistics cannot yet be
accessed. Collection is pending.