TS/MP Management Programming Manual (G06.24+, H06.03+)
ZPWY-MAP- Definitions
NonStop TS/MP Management Programming Manual—540082-001
7-8
ZPWY-MAP-DEF-PATHWAY
The combined values for ZMAXSERVERS in ZPWY-MAP-DEF-SC (or
MAXSERVERS in the PATHCOM SERVER definition) for all server classes is
limited to the value of ZMAXSERVERPROCESSES.
This field is required; there is no default.
ZMAXSPI
is the maximum number of SPI processes that can run simultaneously within the
Pathway subsystem.
The value must be a number from 1 through 100. (Until the Pathway subsystem is
started, only one SPI process or PATHCOM process at a time can open
communication with the PATHMON process.) If you do not assign a value to this
field, the default is 1. For other limits, see Appendix A, Configuration Limits and
Defaults.
ZMAXSTARTUPS
is the maximum number of server classes that can have STARTUP messages
The value must be a number from 0 through 4095. To enable PATHMON process
to run the equivalent of the PATHCOM ALTER SERVER STARTUP command,
specify a maximum of 4094 for this attribute.
Because only one STARTUP definition for each server class counts toward this
limit, the number for this field should not exceed the value for
ZMAXSERVERCLASSES.
This field is required; there is no default.
ZMAXTCPS
This field applies only to Pathway/iTS; a complete description is given in the
Pathway/iTS Management Programming Manual. If you do not have Pathway/iTS
installed, HP recommends setting this value to zero.
This field is required; there is no default.
ZMAXTELLQUEUE
This field applies only to Pathway/iTS; a complete description is given in the
Pathway/iTS Management Programming Manual. If you do not have Pathway/iTS
installed, HP recommends setting this value to zero; the default value is 4.
ZMAXTELLS
This field applies only to Pathway/iTS; a complete description is given in the
Pathway/iTS Management Programming Manual. If you do not have Pathway/iTS
installed, HP recommends setting this value to zero; the default value is 32.