TS/MP Management Programming Manual (G06.24+, H06.03+)
PATHMON Event Messages
NonStop TS/MP Management Programming Manual—540082-001
11-77
Event-Message Range 1000 Through 1999
1149: ZPWY-EVT-PM-INTERNALTABLE
There is insufficient space for additional entries in one of the PATHMON internal 
tables. This is a Pathway subsystem internal error. 
For a description of tokens that are present in this event message but are not listed or 
described below, see Section 10, Event Management. 
Token Descriptions
ZEMS-TKN-EMPHASIS 
has a value of ZSPI-VAL-FALSE.
ZEMS-TKN-EVENTNUMBER 
contains ZPWY-EVT-PM-INTERNALTABLE (1149).
ZEMS-TKN-SUBJECT-MARK 
indicates ZPWY-TKN-PMNAME, which contains the name of the PATHMON 
process that is the subject of this event message.
ZPWY-TKN-EVENTCLASS 
has a value of ZPWY-VAL-ERROREVENT.
Effect. The SCASSIGN, SCDEFINE, SCPARAM, SCPROCESS, and SCSTARTUP 
objects cannot be configured for a server class. If you are running the Pathway/iTS 
product, additional PROG, TELLTERM, and TERM objects cannot be added with the 
ADD command. No server process can be started whose name has not already been 
configured by the user. For configuration limits, see Section A, Configuration Limits 
and Defaults.
Recovery. Contact your HP support representative.
Unconditional Tokens
 ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
 ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-INT.
 ZEMS-TKN-SUBJECT-MARK token-type ZSPI-TYP-SSCTL.
 ZPWY-TKN-PMNAME token-type ZPWY-TYP-PMNAME.
 ZPWY-TKN-EVENTCLASS token-type ZSPI-TYP-ENUM.
Event-Message Text
 *1149* PATHMON, INTERNAL TABLE OVERFLOW -- TOO MANY 
ENTRIES