TS/MP Management Programming Manual (G06.24+, H06.03+)

PATHMON Error Messages
NonStop TS/MP Management Programming Manual540082-001
12-8
Error-Message Range 1000 Through 1999
1012: ZPWY-ERR-PM-DUPNAME
Either the PATHMON process tried to add an object having a name that already exists,
or the PATHMON process tried to start a Pathway/iTS TCP or server process using a
process name that is already active within this Pathway subsystem.
This message usually indicates that there was an attempt to use an object name or a
process name twice. For example, if this is a nested message in a CAN’T GRANT
LINK error (for more information, see the description of event 1007), the process name
for a dynamic server already exists in the list of active server processes and TCPs.
For a description of tokens that are present in this event message but are not listed or
described below, see Section 10, Event Management.
Token Description
ZSPI-TKN-ERROR
contains ZPWY-ERR-PM-DUPNAME.
Effect. The object is not added, or the TCP or server process is not started.
Recovery. Check the object name or the process name associated with the specified
object. Change the names as needed.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST.
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR.
ZPWY-TKN-REQCOMMAND token-type ZSPI-TYP-INT.
ZPWY-TKN-REQOBJECTTYPE token-type ZSPI-TYP-UINT.
ZPWY-TKN-REQnnnNAME token-type ZPWY-TYP-nnnNAME
ZPWY-TKN-ERRCOMMAND token-type ZSPI-TYP-INT.
ZPWY-TKN-ERROBJECTTYPE token-type ZSPI-TYP-UINT.
ZPWY-TKN-nnnNAME token-type ZPWY-TYP-nnnNAME.
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL.