TS/MP Management Programming Manual (G06.24+, H06.03+)
PATHMON Error Messages
NonStop TS/MP Management Programming Manual—540082-001
12-68
Error-Message Range 1000 Through 1999
1104: ZPWY-ERR-PM-TOOMANYSCSTARTUP
The number of startup message definitions has reached the maximum value specified
for the ZMAXSTARTUPS field in ZPWY-DDL-DEF-PATHWAY.
For a description of tokens that are present in this event message but are not listed or
described below, see Section 10, Event Management.
Token Descriptions
ZSPI-TKN-ERROR
contains ZPWY-ERR-PM-TOOMANYSCSTARTUP.
ZPWY-TKN-REQCOMMAND
contains ZPWY-CMD-ADD or ZPWY-CMD-ALTER.
ZPWY-TKN-REQOBJECTTYPE
contains ZPWY-OBJ-SCSTARTUP.
ZPWY-TKN-REQSCSTARTUPNAME
contains the name of the server startup message that could not be added.
Effect. The ADD SCSTARTUP or ALTER SCSTARTUP command fails.
Recovery. Increase the value of the ZMAXSTARTUPS field and reissue the ADD
SCSTARTUP or ALTER SCSTARTUP command.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST.
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR.
ZPWY-TKN-REQCOMMAND token-type ZSPI-TYP-INT.
ZPWY-TKN-REQOBJECTTYPE token-type ZSPI-TYP-UINT.
ZPWY-TKN-REQSCSTARTUPNAME token-type ZPWY-TYP-SCSTARTUPNAME.
ZPWY-TKN-ERROBJECTTYPE token-type ZSPI-TYP-UINT.
ZPWY-TKN-SCSTARTUPNAME token-type ZSPI-TYP-SCSTARTUPNAME.
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL.