1154: ZPWY-ERR-PM-SHUTDOWNTIMEOUT
The shutdown operation has not completed, but the specified timeout value has 
expired.
For a description of tokens that are present in this event message but are not listed or 
described below, see Section 10, Event Management. 
Token Descriptions
ZSPI-TKN-ERROR 
contains ZPWY-ERR-PM-SHUTDOWNTIMEOUT.
ZPWY-TKN-REQCOMMAND 
contains the ZPWY-CMD-SHUTDOWN2 command from the request.
ZPWY-TKN-REQOBJECTTYPE 
contains ZPWY-OBJ-PATHWAY from the request.
Effect. None.
Recovery. This is an informational message only; no corrective action is needed.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST.
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR.
ZPWY-TKN-REQCOMMAND token-type ZSPI-TYP-INT.
ZPWY-TKN-REQOBJECTTYPE token-type ZSPI-TYP-UINT.
ZPWY-TKN-ERRCOMMAND token-type ZSPI-TYP-INT.
ZPWY-TKN-ERROBJECTTYPE token-type ZSPI-TYP-UINT.
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL.
Error-Message Text
 *1154* SHUTDOWN REQUEST TIMED OUT