TS/MP Management Programming Manual (G06.24+, H06.03+)

LINKMON Messages
NonStop TS/MP Management Programming Manual540082-001
13-9
Event Messages in the Range 3000 Through 3999
ZPWY-TKN-EVENTCLASS
has a value of ZPWY-VAL-ERROREVENT.
ZPWY-TKN-INSTRUCTION, ZPWY-TKN-PUNAME, ZPWY-TKN-PUOFFSET,
ZPWY-TKN-PUVERSION, and ZPWY-TKN-TCLPROGFNAME
are conditional tokens specific to this event message; these tokens are included
only if the subject token is ZPWY-TKN-TERMNAME. For descriptions of these
tokens, see the Pathway/iTS Management Programming Manual .
Effect. The operation fails.
Recovery. Isolate and correct the problem within the requester program. See the
TS/MP Pathsend and Server Programming Manual.