TS/MP Management Programming Manual (G06.24+, H06.03+)
SPI and EMS Standard Definitions
NonStop TS/MP Management Programming Manual—540082-001
4-4
EMS Standard Definitions
ZSPI-TKN-SSID
contains ZPWY-VAL-SSID, the subsystem ID of the Pathway subsystem with this 
structure: 
ZSPI-SSN-ZPWY
is the subsystem number assigned to the Pathway subsystem.
EMS Standard Definitions
Definitions whose names begin with ZEMS- are EMS standard definitions. These 
definitions are available to all subsystems that support EMS; they are provided in the 
EMS DDL file (ZSPIDEF.ZEMSDDL) and in the corresponding files for other 
languages.
Table 4-7 and Table 4-8 list the EMS standard definitions for header tokens and data-
portion tokens used in the management programming interface to the Pathway 
subsystem. The tables do not list EMS error numbers or definitions used only in error 
lists. For descriptions of EMS standard definitions, see the EMS Manual. 
def ZPWY-VAL-SSID Tacl SSID.
 02 Z-FILLER token-type ZSPI-DDL-CHAR 8.
 value ZSPI-VAL-TANDEM.
 02 Z-OWNER token-type ZSPI-DDL-CHAR 8.
 redefines Z-FILLER
 02 Z-NUMBER token-type ZSPI-DDL-INT.
 value ZSPI-SSN-ZPWY.
 02 Z-VERSION token-type ZSPI-DDL-INT
 value ZPWY-VAL-VERSION.
end.
Table 4-7. EMS Standard Definitions for Header Tokens
ZEMS-TKN-CONSOLE-PRINT
ZEMS-TKN-CRTPID
ZEMS-TKN-EMPHASIS
ZEMS-TKN-EVENTNUMBER
ZEMS-TKN-GENTIME
ZEMS-TKN-LOGTIME
ZEMS-TKN-PIN
ZEMS-TKN-SYSTEM
ZEMS-TKN-USERID
Table 4-8. EMS Standard Definition for Data-Portion Tokens
ZEMS-TKN-SUBECT-MARK