TS/MP System Management Manual (G06.24+, H06.03+)
PATHMON Environment Control Commands
NonStop TS/MP System Management Manual—541819-001
11- 7
INFO PATHWAY Command
START PATHWAY command at the end of the OUT file before using the file to start a
Pathway environment.
Examples
After you define the attribute values with the SET PATHWAY command, you can use
the INFO PATHWAY command to display those values. This example shows the
output from an INFO PATHWAY command after the attribute values have been
defined:
PATHWAY
MAXASSIGNS 1200 [CURRENTLY 759]
MAXDEFINES 50 [CURRENTLY 5]
MAXLINKMONS 16 [CURRENTLY 0]
MAXPARAMS 30 [CURRENTLY 2]
MAXPATHCOMS 10 [CURRENTLY 1]
MAXSERVERCLASSES 350 [CURRENTLY 320]
MAXSERVERPROCESSES 1750 [CURRENTLY 1544]
MAXSPI 5 [CURRENTLY 0]
MAXSTARTUPS 400 [CURRENTLY 0]
NODEINDEPENDENT ON
OWNER \*.255,63
SECURITY "U"
This example shows the output from an INFO PATHWAY, OBEYFORM command
before the attribute values have been defined:
SET PATHWAY MAXASSIGNS ?
SET PATHWAY MAXDEFINES 0
SET PATHWAY MAXLINKMONS 0
SET PATHWAY MAXPARAMS ?
SET PATHWAY MAXPATHCOMS 5
SET PATHWAY MAXSERVERCLASSES ?
SET PATHWAY MAXSERVERPROCESSES ?
SET PATHWAY MAXSPI 1
SET PATHWAY MAXSTARTUPS ?
SET PATHWAY NODEINDEPENDENT OFF
SET PATHWAY OWNER \TS.8,8
SET PATHWAY SECURITY "U"
These commands direct the Pathway environment information to a file:
INFO/OUT PWINFO/PATHWAY
INFO/OUT PWINFO/PATHWAY, OBEYFORM
Note that you must add the START PATHWAY command to the OUT file before using
the file to start a Pathway environment.
Note. The configuration in this example does not include requester objects that run under
Pathway/iTS, although these objects would be displayed by the INFO PATHWAY command.