TS/MP System Management Manual (G06.24+, H06.03+)
PATHMON Environment Control Commands
NonStop TS/MP System Management Manual—541819-001
11-14
SET PATHWAY Command
PARAM messages for a server class count as one toward this limit, the number for
this attribute should not exceed the value of MAXSERVERCLASSES.
MAXSERVERCLASSES number
is the maximum number of server class descriptions that you can add to the
PATHMON configuration file.
number must be a value from 0 through 4095. To enable the PATHMON process
to process an ALTER SERVER command, specify a maximum of 4094 for this
attribute.
This attribute is required. It has no default.
MAXSERVERPROCESSES number
is the maximum number of server processes that you can define for all server
classes using the MAXSERVERS option of the SET SERVER command.
number must be a value from 0 through 4095. To enable the PATHMON process
to process an ALTER SERVER MAXSERVERS command, specify a maximum of
4094 for this attribute.
This attribute is required. It has no default.
The total of all MAXSERVERS values for all server classes is limited to the value
of MAXSERVERPROCESSES.
MAXSTARTUPS number
is the maximum number of server classes that can have STARTUP messages.
number must be a value from 0 through 4095. To enable the PATHMON process
to process an ALTER SERVER STARTUP command, specify a maximum of 4094
for this attribute.
This attribute is required. It has no default.
Because only one SET SERVER STARTUP definition for each server class counts
toward this limit, the number for this attribute should not exceed the value for
MAXSERVERCLASSES.
MAXTCPS number
This attribute is specific to the Pathway/iTS product. A complete description of this
attribute is given in the
Pathway/iTS System Management Manual.
If your environment does not support Pathway/iTS, it is recommended you specify
0 for the value.
This attribute is required. It has no default.