TS/MP System Management Manual (G06.24+, H06.03+)
PATHCOM Messages (Numbers 2000-2999)
NonStop TS/MP System Management Manual—541819-001
14-18
PATHCOM Messages
2072
Cause. The value specified for the CWD attribute was not an absolute pathname. If
no pathname has been defined for the CWD attribute, then the pathname entered for
the specified OSS attribute is not an absolute pathname.
Effect. If you attempted to set the CWD attribute, the pathname is rejected and the
attribute is not set. If you attempted to add or alter other OSS attributes, the ADD or
ALTER command fails.
Recovery. Either specify an absolute pathname for the given attribute or set an
absolute pathname using the SET SERVER CWD command or the CMDCWD
command. See the descriptions of the OSS attributes in Section 6, Managing the
Pathsend Environment.
2073
Cause. The value specified for the PROCESSTYPE attribute conflicts with values set
for other attributes in the server class.
Effect. The value for the PROCESSTYPE attribute is not changed.
Recovery. Reset all conflicting attribute values before changing the value of
PROCESSTYPE.
2075
Cause. The SET PATHWAY NODEINDEPENDENT attribute is set to ON, but a value
other than \* was specified by the CMDVOL command as the node name in the default
settings for file name expansion.
Effect. The \* node name specification conflicts with the NODEINDEPENDENT
attribute setting.
Recovery. Perform one of these:
•
SET PATHWAY NODEINDEPENDENT to OFF and cold start the PATHWAY
object.
•
Delete the node name value specified by the CMDVOL command.
•
Change the node name specified by the CMDVOL command to \*.
*2072* OSS PATHNAME NOT ABSOLUTE OR DOESN’T RESOLVE TO
ABSOLUTE PATHNAME: attribute-name
*2073* PROCESSTYPE DOESN'T MATCH ATTRIBUTES CURRENTLY SET
*2075* CMDVOL NODE VALUE CONFLICTS WITH PATHWAY
NODEINDEPENDENT ON