V4SE and V8SE Enclosures for NonStop S-Series Servers

4 Status LEDs
Table 4-1 V4SE and V8SE Enclosure LEDs and Their Functions
MeaningStateLED IndicatorComponent
Power is on.GreenStatusV4SE or V8SE enclosure
A fault exists with a FRU
(for example, a hardware
error or a FRU reset).
Amber
Lights during power-on and
when a valid link is
detected.
GreenLink StatusServerNet connection (port
14)
Power is on, and port is
available.
GreenStatus
NOTE: G4SA Slots 6a/7a
Status LEDs are only visible
when the top cover is
removed from the enclosure
G4SA (slots 6a/6b/7a/7b)
1
Power is off.Off
A fault exists.Amber
Ethernet link is connected.OnLink Status
Ethernet link is not
connected.
Off
Data is detected on the port.OnLink Activity
No data is detected on the
port.
Off
Burst of data detected on
port.
Flashing
A fault exists.
NOTE: The fan LED is
visible only when the top
cover is removed from the
enclosure.
AmberStatusFans (Slots 16 and 17)
Power supply is operating.GreenStatusPower supplies (slots 17 and
18)
1 Slot 6b/7b Ethernet LEDs are embedded in the RJ45 connectors.
17