Virtual Hometerm Subsystem (VHS) Manual (G06.24+, H06.04+, J06.03+)
Command Descriptions
Virtual Hometerm Subsystem (VHS) Manual—429311-002
7-13
ALTER Command
SUPPRESS-DISPLAY on-off-value
specifies if the EMS event messages are to appear in the Viewpoint and NonStop
NetMaster (NNM) screens. The default value is OFF.
on-off-value: [ ON | TRUE | OFF | FALSE ]
ON | TRUE
indicates that EMS event messages will not appear in the Viewpoint and NNM
screens.
OFF | FALSE
indicates that EMS event messages will appear in the Viewpoint and NNM
screens.
VHS-LOGGER on-off-value
specifies if VHS is to log in its primary log files. The default value is ON.
on-off-value: [ ON | TRUE | OFF | FALSE ]
ON | TRUE
indicates that VHS will log in its primary log files.
OFF | FALSE
indicates that VHS will not log in its primary log files.
Considerations
•
If the specified CPU number is the CPU of the primary process, a warning
message is returned.
•
If the specified CPU number is not the CPU of the backup process or the primary
process, an error message is returned.