Virtual Hometerm Subsystem (VHS) Manual (G06.24+, H06.04+, J06.03+)

Command Descriptions
Virtual Hometerm Subsystem (VHS) Manual429311-002
7-31
INFO Command
when the VHS process is started, a default prompt file is assigned by the VHS
process.
Next save file is the name of the next saveabend file to be created (when a
process traps into Inspect/eInspect, VHS creates this saveabend file).
Accept-ext-ascii-character allows the VHS process to accept or not accept non-
ASCII characters. If the Accept-ext-ascii-character is set to ON, VHS accepts non-
ASCII characters. If Accept-ext-ascii-character is set to OFF, VHS does not accept
non-ASCII characters. By default, VHS sets Accept-ext-ascii-character to OFF.
Add-text-to-event is the parameter that specifies if the token text is to be added to
all EMS events. If the Add-text-to-event is set to ON, VHS will add the token text to
all EMS event messages. If Add-text-to-event is set to OFF, VHS will not add the
token text to all EMS messages. By default, VHS sets Add-text-to-event to ON.
Automatic-inspect-processing specifies if VHS does not process
Inspect/eInspect prompts; they are managed via the VHS Prompt Browser screen.
When Automatic-inspect-processing is ON, VHS automatically handles
Inspect/eInspect prompts. When Automatic-inspect-processing is OFF, VHS does
not process Inspect/eInspect prompts; they will be managed via the VHS Prompt
Browser screen. By default, VHS sets Automatic-inspect-processing to ON.
Backup-creation-message-delay is the delay in minutes between each
occurrence of the backup creation failure message. The delay must be between 0
and 999. If there is no delay specified, the default delay is 5 minutes.
Environment-name is the name of the VHS process environment. The string
value assigned to Environment-name must be between quotes ( " ). The first
character must be alphabetic. All other characters can be alphabetic or numeric or
a “-”. The environment name length can be from 1 to 8 characters long.
File-code is used for the primary log file creation. The numeric value assigned to
File-code must be between 0 and 65535. If there is no numeric value assigned
then the default value is 0.
Generate-display-event specifies if an EMS event message is to be generated for
a display type message. When Generate-display-event is set to ON, VHS
generates EMS events for display type messages. When Generate-display-event
is set to OFF, VHS does not generate EMS events for display type messages. By
default, VHS sets Generate-display-event to ON.
Generate-inspect-event specifies if an EMS event message must be generated
for Inspect type messages. When Generate-inspect-event is set to ON VHS
generates EMS events for Inspect type messages. When Generate-inspect-event
is set to OFF VHS does not generate EMS events for Inspect type messages. By
default, VHS sets Generate-inspect-event to ON.
Generate-prompt-event specifies if an EMS event message must be generated
for a prompt type message. When Generate-prompt-event is set to ON, VHS
generates EMS events for prompt type messages. When Generate-prompt-event