Virtual Hometerm Subsystem (VHS) Manual (G06.24+, H06.04+, J06.03+)

VHS Event Messages
Virtual Hometerm Subsystem (VHS) Manual429311-002
D-17
3: ZVHS-EVT-INSPECT-OBEY
Unconditional Tokens
ZSPI-TKN-SSID
is the subsystem ID for VHS and is described in the SPI Programming Manual.
The value of this token is always ZVHS-VAL-SSID.
ZEMS-TKN-EVENTNUMBER
is the event message number. The value for this event message is ZVHS-EVT-
INSPECT-OBEY (3).
ZEMS-TKN-SUBJECT-MARK
is the standard EMS token that immediately precedes the subject token ZVHS-
TKN-APPLICATION-NAME.
ZEMS-TKN-EMPHASIS
is set to ZSPI-VAL-TRUE because this event message is critical.
(ZEMS-TKN-) CPU, PROC-DESC, GENTIME, LOGTIME, PIN, SYSTEM,
USERID and TEXT
are described under EMS Standard Definitions on page D-5.
(ZEMS-TKN-) CPU, CRTPID, GENTIME, LOGTIME, PIN, SYSTEM, USERID
and TEXT
are described under EMS Standard Definitions on page D-5.
ZEMS-TKN-SUPPRESS-DISPLAY
is set to ZSPI-VAL-FALSE.
ZVHS-TKN-APPLICATION-NAME
is the name of the application that has gone into Inspect/eInspect.
ZVHS-TKN-ENVIRONMENT-NAME
is the name of the environment of this VHS. If no environment name is defined
using the VHS startup parameter ENVIRONMENT-PARAM, then the default value
is VHS.
Event-Message Text
timestamp pid environment-name: Process process-id-string
entered Inspect/eInspect. The command "command-string" has
been sent to Inspect/eInspect. Program file program-name.
Primary log file primary-log-name.