Virtual TapeServer 6.02.00 Installation Guide

HP Virtual TapeServer Installation Guide 55 HP Part Number 528654-006 Sept 2006
a) 1
st
SCSI card to be removed: Remove the SCSI card in slot 3 and install the 1
st
Fibre
Channel card in slot 3.
b) 2
nd
SCSI card to be removed. Remove the SCSI card in slot 2 and install the 2
nd
Fibre
Channel card in slot 2.
Image 2 VT5900-C PCI Riser cage showing slot numbers along the right side.
VT5901. There is always a Fibre Channel card in slot 3, the top slot. There should be no reason to
remove this card. Slots 2 and 1 contain SCSI cards. A picture showing these slots follows – Image 2).
The following order of SCSI card removal must be followed:
Note: Before installing the VT5901 Fibre Channel card(s), write down the World Wide Name (WWN) of each Fibre Channel port.
WWN’s are required to start Fibre Channel virtual tape drives on a NonStop server.
a) 1
st
SCSI card to be removed: Remove the SCSI card in slot 2 and install the 1
st
Fibre
Channel card in slot 2.
b) 2
nd
SCSI card to be removed. Remove the SCSI card in slot 1 and install the 2
nd
Fibre
Channel card in slot 1.
Image 3 VT5901 PCI Riser cage showing slot numbers along the right side.
3) Once all the desired Fibre Channel upgrade cards have been installed in the appropriate slots, check to
make sure the blue clips are firmly seated and locked in place on each slot. Then, re-install the PCI
Riser cage into the DL380 chassis. Once aligned, firmly press the module into place. Re-tighten the
two blue pull tabs on the PCI Riser cage.