Virtual TapeServer 6.04.02 for NonStop Servers Release Notes
Known Issues | 15
Cartridge Status pop-up dialog is not updated while a cartridge is mounted. If
you display the Cartridge pop-up dialog by clicking a link in the size (MB) column of the
Virtual Media - Operation page and then the cartridge is mounted, the data is not
updated on the pop-up. (TL-2350)
WORKAROUND: View this information when the cartridge is not mounted.
Scan/Cleanup page performance is slow. Loading the Scan/Cleanup page is slow if a
large number of cartridges exists. It takes about a minute for a pool containing 1,000
cartridges. (TL-2358)
Download link for System Message Log does not work. If you click the download
link on the Examine System Logs page, the URL fails to load when you click this link.
(TL-2359)
WORKAROUND: Log in to VTS and copy the /var/log/messages file.
Cartridge sizes are not displayed properly. Cartridges created with 1TB, 1GB, or
1MB limits will display, respectively, as 1024GB, 1024MB, and 1024K. However, 2TB
cartridges display as 2TB, 2GB carts display as 2GB, and 2MB cartridges display as 2MB.
(TL-2365)
After logging in as admin for SecureVTS functions in an open system, changing
access controls to default closed results in excessive numbers of dialogs.
SecureVTS requires login for certain functions in the UI. If you start with an open system
and then close it by setting 'default closed' in 'Access Control', you are continually
prompted for your username and password as you navigate around. Once you enter
credentials on a password section, you are allowed to go back to that section. (TL-970)
WORKAROUND: Restore the defaults for closed access control, close the browser, and
relaunch the browser.
Clicking the browser Back button after creating a system restore image causes
download to start again. After clicking Supervisor Functions -> Create VTS System
Restore Image, a file download dialog box is displayed. After the file is downloaded or
canceled, you are presented with a web page indicating what has happened, but no return
link is displayed. Clicking the browser back button causes VTS to begin creating the
system restore image again. (TL-2179)
WORKAROUND: Use another navigation link on the interface, not the browser’s back
button.
@secure and other non-cartridge files are displayed in the interface. When a new
pool is created and the 'Encrypted' option is selected, '@secure' is listed as one of the
cartridges as well as other non-cartridge files. This is not a cartridge and cannot perform
any cartridge actions such as delete and erase on it. (TL-2341)
Pop-up windows display stale, cached data. When pop-up windows are displayed,
some browsers may display stale, cached data rather than the current information. (TL-
2342)
WORKAROUND: To ensure that the information is accurate, use your browser's refresh
or reload function to update the information.
Long pool names cause cartridge creation to fail but report success. If you try to
create cartridges in a pool with a path name of 255 characters or greater, the cartridge
creation reports success but it fails. (TL-1869)
WORKAROUND: Create pools with path names less than 255 characters.