Virtual TapeServer 6.04.02 for NonStop Servers Release Notes
Known Issues | 16
 Firefox shows negative values on the System Status page. If you are using the 
Firefox browser to view the VTS web interface, negative values may be displayed in the 
kb/sec column in the Connections table on the System Status page. (TL-347)
 Firefox improperly renders Cartridge Maintenance page when Multiple Select 
checkbox is unchecked. If you use Firefox to view the interface and you deselect the 
Multiple Select option on the Cartridge Maintenance page, the browser renders the page 
incorrectly, displaying items in the wrong place and not preserving information. (TL-346)
WORKAROUND: Click the Clear Form button to correct the display problem.
 User and group changes can be applied but not saved as part of the Custom 
Defaults. On the Access Control page, you can save user and group settings by clicking 
the Save as CUSTOM button but subsequent changes to the custom defaults cannot be 
saved. (TL-377)
 Must click Restore CUSTOM Defaults button twice to display the “Users and 
Groups” and “Rights” sections of the page. When you click the Restore CUSTOM 
Defaults button, the “Users and Groups” and “Rights” sections of the Access Control page 
are not displayed. You must click the button again to display these sections and restore 
the custom defaults. (TL-378)
 If too much data is transferred in a refresh period, the transfer rate and 
compression ratio displayed on the System Status page may be inaccurate. If 
more than 2GB of data is written during a refresh period of the System Status page, the 
transfer rate and compression ratio may be invalid. (TL-880)
 The selected menu item does not correspond to the displayed page when the 
browser Back or Forward buttons are used to navigate the web interface. If you 
use the Back or Forward button provided by the browser to navigate to pages on the web 
interface, the previously viewed menu item is displayed on the main page but the 
highlighted menu item does not go back or forward to the corresponding menu item. (TL-
570)
 Cannot cancel a manual mount request using the Cancel button. If you press the 
Mount button to mount a cartridge then press the Cancel button instead of the OK button, 
the cartridge is mounted on the VTD. The operation is not cancelled. (TL-543)
 The Written metadata date option on the Scan/Cleanup page displays Never 
instead of the correct date/time. On the Meta Data Control Panel on the Scan/
Cleanup page, the Written metadata option displays Never instead of the correct date/
time if you change the cartridge size or write to a cartridge. (TL-264)
SecureVTS
 SecureVTS with remote key generator does not encrypt cartridges. If SecureVTS 
is configured to use a remote key generator, the local host cannot encrypt cartridges. (TL-
3171)
WORKAROUND: Backup the remote keyserver database, delete the “localhost” 
keyserver on the remote server, re-add the localhost keyserver on the remote server, 
restore the keyserver database from backup.