Virtual TapeServer 6.04.02 for NonStop Servers Release Notes

Known Issues | 16
Firefox shows negative values on the System Status page. If you are using the
Firefox browser to view the VTS web interface, negative values may be displayed in the
kb/sec column in the Connections table on the System Status page. (TL-347)
Firefox improperly renders Cartridge Maintenance page when Multiple Select
checkbox is unchecked. If you use Firefox to view the interface and you deselect the
Multiple Select option on the Cartridge Maintenance page, the browser renders the page
incorrectly, displaying items in the wrong place and not preserving information. (TL-346)
WORKAROUND: Click the Clear Form button to correct the display problem.
User and group changes can be applied but not saved as part of the Custom
Defaults. On the Access Control page, you can save user and group settings by clicking
the Save as CUSTOM button but subsequent changes to the custom defaults cannot be
saved. (TL-377)
Must click Restore CUSTOM Defaults button twice to display the “Users and
Groups” and “Rights” sections of the page. When you click the Restore CUSTOM
Defaults button, the “Users and Groups” and “Rights” sections of the Access Control page
are not displayed. You must click the button again to display these sections and restore
the custom defaults. (TL-378)
If too much data is transferred in a refresh period, the transfer rate and
compression ratio displayed on the System Status page may be inaccurate. If
more than 2GB of data is written during a refresh period of the System Status page, the
transfer rate and compression ratio may be invalid. (TL-880)
The selected menu item does not correspond to the displayed page when the
browser Back or Forward buttons are used to navigate the web interface. If you
use the Back or Forward button provided by the browser to navigate to pages on the web
interface, the previously viewed menu item is displayed on the main page but the
highlighted menu item does not go back or forward to the corresponding menu item. (TL-
570)
Cannot cancel a manual mount request using the Cancel button. If you press the
Mount button to mount a cartridge then press the Cancel button instead of the OK button,
the cartridge is mounted on the VTD. The operation is not cancelled. (TL-543)
The Written metadata date option on the Scan/Cleanup page displays Never
instead of the correct date/time. On the Meta Data Control Panel on the Scan/
Cleanup page, the Written metadata option displays Never instead of the correct date/
time if you change the cartridge size or write to a cartridge. (TL-264)
SecureVTS
SecureVTS with remote key generator does not encrypt cartridges. If SecureVTS
is configured to use a remote key generator, the local host cannot encrypt cartridges. (TL-
3171)
WORKAROUND: Backup the remote keyserver database, delete the “localhost”
keyserver on the remote server, re-add the localhost keyserver on the remote server,
restore the keyserver database from backup.