Virtual TapeServer 6.04.03 for NonStop Servers Supplemental Installation Guide
SCSI-to-Fibre Channel Adapter Upgrade | 35
f. Click Set Limits.
7. Reboot VTS.
8. Use the VTS web interface to reconfigure a virtual tape connection.
After the Fibre Channel ports are configured as virtual devices, the final step in this
process is to reconfigure the virtual tape connections. Virtual tape connections originally
set up as SCSI need to be edited for use on a Fibre Channel bus.
Refer to the steps documented in the Virtual TapeServer Installation Guide. When
changing the properties, change the TARGET from 5 to 0 from the drop-down box. Repeat
the steps for each virtual tape connection that needs to be updated.
9. When the startup process is complete, open a terminal window on VTS and log in. Then,
enter su - to become root. Using a text editor, remove the lines that were commented out
in step
2e on page 32 (remove the # sign in front of each vault, such as #LABEL=/
VAULT01 becomes LABEL=/VAULT01). Do this for all vaults.
10. Save all changes and exit the editor.
11. Reboot VTS.
5 A 2 2G Fibre $VTAPE02
5 B 3 2G Fibre $VTAPE03
PCI Slot Bus Number Card Type Virtual Tape Name