Virtual TapeServer 6.04.03 Operations and Administration Guide
90 | Using Scan/Cleanup
cleanup_minimum_size_
GB
and
cleanup_minimum_size_
MB
Define which files to ignore based on size by
using either cleanup_minimum_size_MB
or cleanup_minimum_size_GB. The
specified value is used to set the minimum
file size to erase. Some installations have
many small virtual tapes and do not require
that they be erased. For larger tape sizes,
use the cleanup_minimum_size_GB
parameter; for smaller sizes, use the
cleanup_minimum_size_MB parameter.
A typical setting for the
cleanup_minimum_size_GB parameter is
8, which specifies not to erase virtual tapes
with less than 8GB of data.
(To disable Scan/Cleanup so that no
cartridges are erased, set
cleanup_enable="NO".)
Default value: 0 (for both parameters)
Integer
cleanup_show_NO Controls whether VTS should display the
NO rows on the Scan/Cleanup page. Many
of the virtual tapes will not be scheduled for
erasure. To make the display smaller and
simpler, the NO rows are suppressed. When
this parameter is set to NO, a small button
is shown that permits the user to
temporarily override this parameter and
show the NO rows.
Default value: NO
YES or NO
cleanup_show_erase_
column
Shows or hides the Erase meta data column
in the Status Table. The date of the last
erasure may not be important to a
particular installation of VTS. However,
this information may easily be viewed by
enabling this feature.
Default value: NO
YES or NO
cleanup_show_size_
column
Shows or hides the Size column in the
Status Table.
Default value: NO
YES or NO
meta_control_panel Shows or hides the Meta Data Control
Panel, which enables you to read and write
metadata on the virtual tape. Set this
parameter only if diagnosing problems or
instructed to do so by Support.
Default value: NO
YES or NO
Parameter Description Values