Virtual TapeServer 6.04.03.02 for NonStop Servers Release Notes

Known Issues | 24
Scan/Cleanup is not enabled though the web interface indicates that it is.
scanat.log includes the “Scan/cleanup configuration error - auto erase not enabled.”
message, but the web interface shows that auto erase is enabled, and Scan/Cleanup did
not run. (TL-3702)
WORKAROUND: If necessary, enable and configure Scan/Cleanup as described in the
Installation Guide.
Cartridges are not erased when expected if cleanup_autoerase is configured.
Scheduled erasures do not occur when scheduled, though they are eventually erased. (TL-
2388)
Scan/Cleanup page size column reports size on disk of cartridges rather than
data size. The size column on the Scan/Cleanup page shows the file size on disk. Thus,
cartridge data is different on this page than on other pages in the web interface. (TL-2158)
Scan/Cleanup menu option may not be available. Customers using the Scan/
Cleanup feature should confirm that the VTS configuration file contains the
menu_ScanCleanup=”YES” parameter, which displays the scan/cleanup option from
the window drop-down list on the Virtual Media page (TL-505).
WORKAROUND: Add this line to the VTS configuration file. To edit the VTS
configuration file, click Supervisor Functions on the navigation pane, and then click
Edit Configuration File under the Utilities section of the resulting page.
Cartridge having less than minimum size is listed as erasable in Scan/Cleanup
after migration. If a cartridge is below the size specified by the cleanup_minimum_size_
MB parameter, the cartridge is scheduled to be erased by Scan/Cleanup after migration.
This is incorrect behavior; it should not be scheduled for erasure. (TL-444)
Migration
Cartridge IDs are not returned to hsm.log after a backup that spans tapes. After
a backup job that spans multiple cartridges, the cartridge IDs are not returned in the
hsm.log. (TL-4534)
Incorrect error message logged after successful manual migration. If you
configure the Netbackup client on the VTS server and click the Migrate button, the
migration may succeed but hsmput.log contains the message indicating a network read
failure. (TL-4372)
Default vts.conf file does not include migrate_all parameter. This parameter can
be set to allow all cartridges, including empty ones, to be migrated. This parameter is not
present in the default configuration file. (TL-3950)
Migrate all does not export all cartridges. If the migrate_all parameter is set,
cartridges are migrated but not exported. (TL-3954)
Cartridge not ejected after migration by Legato. After migration is completed, the
cartridge should be ejected and put back in the tape slot. If Legato is used to migrate the
tape, the tape is not ejected as expected. (TL-2390)
Misconfigured migration settings cause “Error: Can't find any files with data to
backup” error. If you do not specify a BMA in vts.conf, or if you misconfigure a
migration setting, the “Error: Can't find any files with data to backup message is
displayed, which does not indicate the problem. (TL-2645)