Virtual TapeServer 6.04.04 for NonStop Servers Operations and Administration Guide
70 | Using Scan/Cleanup
cleanup_minimum_size_
GB
and
cleanup_minimum_size_
MB
Define which files to ignore based on size by 
using either cleanup_minimum_size_MB 
or cleanup_minimum_size_GB. The 
specified value is used to set the minimum 
file size to erase. Some installations have 
many small virtual tapes and do not require 
that they be erased. For larger tape sizes, 
use the cleanup_minimum_size_GB 
parameter; for smaller sizes, use the 
cleanup_minimum_size_MB parameter. 
A typical setting for the 
cleanup_minimum_size_GB parameter is 
8, which specifies not to erase virtual tapes 
with less than 8GB of data. 
(To disable Scan/Cleanup so that no 
cartridges are erased, set 
cleanup_enable="NO".)
Default value: 0 (for both parameters)
Integer
cleanup_show_NO Controls whether VTS should display the 
NO rows on the Scan/Cleanup page. Many 
of the virtual tapes will not be scheduled for 
erasure. To make the display smaller and 
simpler, the NO rows are suppressed. When 
this parameter is set to NO, a small button 
is shown that permits the user to 
temporarily override this parameter and 
show the NO rows. 
Default value: NO
YES or NO
cleanup_show_erase_ 
column
Shows or hides the Erase meta data column 
in the Status Table. The date of the last 
erasure may not be important to a 
particular installation of VTS. However, 
this information may easily be viewed by 
enabling this feature.
Default value: NO
YES or NO
cleanup_show_size_ 
column
Shows or hides the Size column in the 
Status Table.
Default value: NO
YES or NO
meta_control_panel Shows or hides the Meta Data Control 
Panel, which enables you to read and write 
metadata on the virtual tape. Set this 
parameter only if diagnosing problems or 
instructed to do so by Support.
Default value: NO
YES or NO
Parameter Description Values