Virtual TapeServer 6.04.05 for NonStop Servers Release Notes
Troubleshooting | 38
 Error message displayed on console after the server is booted for the first time. 
Messages similar to the following are displayed on the console the first time VTS is 
booted:
Mounting other filesystems: [ OK ] 
Starting hp-ilo:/opt/hp/hp-ilo/drivers/char/hp_ilo/CpqCiKlx.c: In 
functionoctl32_handler':
/opt/hp/hp-ilo/drivers/char/hp_ilo/CpqCiKlx.c:680: warning: 
assignment makes pointer from integer without a cast
/opt/hp/hp-ilo/drivers/char/hp_ilo/CpqCiKlx.c:796: warning: cast from 
pointer to integer of different size
/opt/hp/hp-ilo/drivers/char/hp_ilo/CpqCiKlx.c:796: warning: cast from 
pointer to integer of different size
...
These messages can be ignored. (TL-2079)
 The “mount /dev/cdrom” command no longer works because CD media is 
handled differently. The new VTS operating system (CentOS 5.2) handles removable 
media mounting differently than in previous releases. Removable media is automounted 
on /media through the Hardware Abstraction Layer (HAL) without entries in /etc/fstab in 
much the same manner as removable media in Windows XP. From the console, however, 
media is not automounted. (TL-1755)
 Linux kernel error message logged to /var/log/messages. Messages similar to the 
following are logged to /var/log/messages:
Jul 10 16:23:23 localhost kernel: Contact your BIOS vendor to see if 
the E752x error registers can be safely un-hidden
This is caused by a known Linux kernel driver issue for CentOS 5.2 and does not hinder 
system operation. Ignore these messages. (TL-1853)
 Must use the rewinding name of a drive for import_export_drive_exclude 
parameter in vts.conf. When specifying devices to be excluded from imports or exports 
using the import_export_drive_exclude parameter in vts.conf, be sure to use the 
rewinding name of the drive rather than the non-rewinding name. That is, use '/dev/st0', 
not '/dev/nst0'. (TL-1962)
Web interface
 TapeServer and EMS service can be stopped and started by user who is not 
logged in. If the user did not log in on an open system, the user can access the 
TapeServer and EMS links on the Supervisory Functions page. (TL-3440)
 Logging in to web interface on localhost does not redirect to secure page. When 
accessing the web interface from the localhost, HTTPS is not needed because data is not 
transmitted. (TL-3643) 
 Browser may display old data or errors if not refreshed. If an unexpected error 
occurs or data appears to be old, refresh the browser. Old data is cached and may need to 
be cleared. (TL-1662)
 A - is displayed for a cartridge limit for old cartridges. Cartridges that existed 
before VTS was upgraded to 6.04.01 will display a - for the limit, but all new cartridges 
will display 2TB if not given a limit. When the old cartridge is loaded writable, the size 
limit will be updated to be writable, and the size limit will be updated to 2TB. (TL-2173)