Virtual TapeServer 8.0 Supplemental Installation Guide
40 | SCSI-to-Fibre Channel Adapter Upgrade
d. Click Submit. Confirm to reboot the server.
8. Use the VTS web interface to reconfigure a VTD.
After the Fibre Channel ports are configured as virtual devices, the final step in this 
process is to reconfigure the VTDs. VTDs originally set up as SCSI need to be edited for 
use on a Fibre Channel port.
Refer to the steps documented in the online help. When changing the properties, change 
the Target from 5 to 0 from the drop-down box. Repeat the steps for each VTD that needs 
to be updated.
9. When the startup process is complete, open a terminal window on VTS and log in. Then, 
enter su - to become root. Using a text editor, remove the lines that were commented out 
in step 
3e on page 37 (remove the # sign in front of each vault, such as #LABEL=/
VAULT01 becomes LABEL=/VAULT01). Do this for all vaults.
10. Save all changes and exit the editor.
11. Reboot VTS.
3 A N/A (left open for P800 
controller card)
3 B N/A (left open for P800 
controller card)
4 A 0 2G Fibre $VTAPE00
4 B 1 2G Fibre $VTAPE01
5 A 2 2G Fibre $VTAPE02
5 B 3 2G Fibre $VTAPE03
PCI Slot Bus Number Card Type Virtual Tape Name