Virtual TapeServer 8.2 Configuration Guide
Table Of Contents
- Virtual TapeServer for NonStop Servers Configuration Guide
- Preface
- Introduction
- Overview of Tasks
- Reconfiguring Vaults
- Enabling Licensed Features
- Configuring Ports
- Creating and Managing VTLs and VTDs
- Enabling and Performing Tape-to-tape Exports
- Enabling and Performing Stacked Exports
- Enabling and Configuring Data Replication
- Enabling and Configuring Role Swapping
- Configuring EMS Communication
- Enabling and Configuring Data Encryption
- Creating and Managing Virtual Media
- Enabling and Configuring Scan/Cleanup
- Configuring User Accounts
- Configuring Web Interface Preferences
- Managing the VTS Server
- Troubleshooting
- Maintaining GFS for VTS
- Reinstalling and Restoring VTS
- Attaching External Devices after Initial Deployment
- TCP/IP Ports and Protocols
- Index
176 | Attaching External Devices after Initial Deployment
/dev/sg6 6 0 0 5 5 /dev/scd5
/dev/sg7 6 0 0 6 5 /dev/scd6
Then, find the nst0 entry (tape drive) attached and then enter this command:
sg_inq /dev/sgn
where sgn is the number that matches the /dev/nstn device. For the output listed above,
you would enter sg_inq /dev/sg0. Here is an example of the output from this command:
standard INQUIRY:
PQual=0 Device_type=1 RMB=1 [ANSI_version=4] version=0x04
[AERC=0] [TrmTsk=0] NormACA=0 HiSUP=0 Resp_data_format=2
SCCS=0 ACC=0 ALUA=0 3PC=0 Protect=0
BQue=0 EncServ=0 MultiP=0 MChngr=0 [ACKREQQ=0] Addr16=1
[RelAdr=0] WBus16=1 Sync=1 Linked=0 [TranDis=0] CmdQue=0
Clocking=0x3 QAS=0 IUS=0
length=74 (0x4a) Peripheral device type: tape
Vendor identification: CERTANCE
Product identification: ULTRIUM 3
Product revision level: 1770
Product serial number: JD006D2
Repeat for each tape drive that was added.