Virtual TapeServer 8.4 Configuration Guide
232 | Virtual TapeServer Configuration Guide
/dev/sg3 6 0 0 2 5 /dev/scd2
/dev/sg4 6 0 0 3 5 /dev/scd3
/dev/sg5 6 0 0 4 5 /dev/scd4
/dev/sg6 6 0 0 5 5 /dev/scd5
/dev/sg7 6 0 0 6 5 /dev/scd6
Then, find the nst0 entry (tape drive) attached and then enter this command:
sg_inq /dev/sgn
where sgn is the number that matches the /dev/nstn device. For the output listed above, you
would enter sg_inq /dev/sg0. Here is an example of the output from this command:
standard INQUIRY:
PQual=0 Device_type=1 RMB=1 [ANSI_version=4] version=0x04
[AERC=0] [TrmTsk=0] NormACA=0 HiSUP=0 Resp_data_format=2
SCCS=0 ACC=0 ALUA=0 3PC=0 Protect=0
BQue=0 EncServ=0 MultiP=0 MChngr=0 [ACKREQQ=0] Addr16=1
[RelAdr=0] WBus16=1 Sync=1 Linked=0 [TranDis=0] CmdQue=0
Clocking=0x3 QAS=0 IUS=0
length=74 (0x4a) Peripheral device type: tape
Vendor identification: CERTANCE
Product identification: ULTRIUM 3
Product revision level: 1770
Product serial number: JD006D2
Repeat for each tape drive that was added.