Virtual TapeServer 8.4 Release Notes

Known Issues | 17
Known Issues
The following known issues, or “errata,” apply to the 8.4 release. The issue tracking number is
provided in parentheses. Refer to this number when making inquiries to Technical Support.
There is a table of tracking numbers listed in
ascending order, with the summary and
document section number, in Issue Index on
page 55.
Hardware, configuration, and hardware replacement
Adding or removing a HBA may cause the port configuration to change. Adding
or removing a HBA in a VTS may cause the port configuration on the Virtual Devices page
to change. (TL-7750)
WORKAROUND: Reco
nfigure the ports and resubmit the changes on the Virtual Devices
page.
VTS installation using a TEAC DVD drive stops with an error message. VTS
installation on a VT5900-K, VT5900-M or VT5900-O platform using a TEAC DVD drive
(Model PU-DVR10-91) stops with the error message “Error downloading kickstart file”.
This is due to the USB driver being disabled during the installation. (TL-3515, EAR-9117)
Cannot dedicate a network for data only if multiple systems do not share a
common network. For this configuration, netconfig cannot correctly configure the
appliances. (TL-7531)
netconfig allows invalid values for IP addresses, net masks, and hostnames.
Error messages are only shown when the operating system sees errors from these set
values. (TL-7599)
WORKAROUND: Rerun netconfig with the correct
values to correctly set the values.
VTS attached to HP EVA storage systems may experience long boot delays. This
is due to a firmware incompatibility with the EVA and the Linux software RAID driver.
For more information, see
http://h20566.www2.hp.com/portal/site/hpsc/template.PAGE/p
ublic/kb/docDisplay/
?javax.portlet.tpst=ba847bafb2a2d782fcbb0710b053ce01&javax.portlet.prp_ba847bafb2a
2d782fcbb0710b053ce01=wsrp-navigationalState%3DdocId%25253Demr_na-
c01914818%25257CdocLocale%25253Den&javax.portlet.begCacheTok=com.vignette.cach
etoken&javax.portlet.endCacheTok=com.vignette.cachetoken (Document ID C01914818
published October 2009). (TL-7179)
WORKAROUND: Th
e dmraid software RAID feature is not used with VTS and may be
safely disabled to overcome this delay.
Message no longer displayed to power off SCSI converter. When stopping
Tapeserver, the “Please power OFF all SCSI converters connected to this Virtual
TapeServer. Then Click 'OK'.” message is no longer displayed. However, you must power
off the SCSI converters when stopping Tapeserver. (TL-7336)
SCSI virtual devices may not appear immediately to AS/400. (TL-7320)
WORKAROUND: Reboot
VTS and the device should be discovered.
netconfig will not allow setting a non-default static route. When using netconfig to
configure interfaces, there may be a need to set a different gateway for eth1 other than
the default gateway. There is currently no way to do this using netconfig. (TL-7340)