Viewing the Event Log
From the network management application or SNMP MIB browser, it is possible to view the event
log of the VT5900-SA from the connUnitEventTable leaf.
Format of event log entry: Event Severity, Type, OID Value.
• Event Severity is an integer in the range of 0 to 9 and correspond to the filter values selected
from the FA MIB 2.2 Event Filter Settings menu selected from the SNMP Configuration
menu.
• Type can be Status (for example, a reboot event), configuration (for example, a change to
settings), topology (for example, a discovery event), other (for example, HP internal
information), or unknown (for example, an unclassified event).
• OID Value is the Object Identifier associated with this event.
Each entry in the event log also includes a 4-digit time stamp indicating the elapsed time since the
last boot. The first two digits of the time stamp represent seconds and the second two digits
represent hundredths of a second.
Fibre Alliance MIB 2.2 Table
The following table contains all the elements within the FA MIB 2.2.
OID Name Type
1.3.6.1.3 experimental NODE
1.3.6.1.3.94 fcmgmt NODE
1.3.6.1.3.94.1 connSet NODE
1.3.6.1.3.94.1.1 uNumber LEAF INTEGER
1.3.6.1.3.94.1.2 systemURL LEAF DisplayString
1.3.6.1.3.94.1.3 statusChangeTime LEAF TimeTicks
1.3.6.1.3.94.1.4 configurationChangeTime LEAF TimeTicks
1.3.6.1.3.94.1.5 connUnitTableChangeTime LEAF TimeTicks
1.3.6.1.3.94.1.6 connUnitTable NODE
1.3.6.1.3.94.1.6.1 connUnitEntry NODE
1.3.6.1.3.94.1.6.1.1 connUnitId LEAF DisplayString
1.3.6.1.3.94.1.6.1.2 connUnitGlobalId LEAF FcGlobalId
1.3.6.1.3.94.1.6.1.3 connUnitType LEAF FcUnitType
1.3.6.1.3.94.1.6.1.4 connUnitNumports LEAF INTEGER
1.3.6.1.3.94.1.6.1.5 connUnitState LEAF INTEGER
1.3.6.1.3.94.1.6.1.6 connUnitStatus LEAF INTEGER
1.3.6.1.3.94.1.6.1.7 connUnitProduct LEAF DisplayString