Virtual TapeServer SCSI-to-FC Adapter User Manual
2-4
Chapter 2: Getting Started
6. Attach the ear brackets to the VT5900-SA, using two of the #6-32x.312 Phillips screws on
each side (as shown in Figure 2-3 below). Position the front of each bracket next to the end of
the VT5900-SA that will be facing out of the rack (see Step 7 for more information). Tighten
the screws securely.
Figure 2-3. Attaching ear brackets
7. If you are mounting the VT5900-SA in the rack with the ports facing inside the rack (shown in
Figure 2-4) or with the ports facing outside the rack (shown in Figure 2-5), attach the front of
the mounting brackets to the rack using two of the #M6x12 Phillips screws for the front of
each ear bracket. Tighten the screws securely.
Warning: To reduce injury or equipment damage, the mounting brackets must be level. If the
brackets are not level, the VT5900-SA cannot be installed correctly.