Virtual TapeServer SCSI-to-FC Adapter User Manual

6-17
Chapter 6: Using Visual Manager
Main Menu Ports FC Port 0
This menu allows viewing or changing current settings for the Fibre Channel port.
Figure 6-15. FC Port 0 screen
To make any changes, modify the entries as described below and then select the Submit button.
Link Status indicates whether the port link status is currently up, down, or pending.
Port Mode can be set to either Auto Sense (default setting) or N_Port Mode.
In Auto Sense mode, the VT5900-SA FC port tries to come up as a loop and if not successful
then tries to come up as a fabric. If the port comes up as a loop, it then determines whether it’s
on a private or public loop.
In N_Port mode, the VT5900-SAs FC port skips trying to come up as a loop and instead tries
coming up as a fabric only. If the VT5900-SA is on a loop and N_Port mode is selected, an
error in communication may occur.
Use Hard ALPA sets the Hard AL_PA usage, which can be Enabled or Disabled. If set to
Enabled, a unique one-byte valid value (derived from an Arbitrated Loop Topology as
defined in ANSI specification FC_AL ver 4.5) is used for the Fibre Channel configuration.
When configuring the FC AL_PA, the VT5900-SA presents a list of loop addresses along with
the corresponding AL_PA. From here, the user can select the loop address desired.
When Hard AL_PA usage is set to Enabled, you can set the Hard AL_PA value by selecting
the SET ALPA button and entering a node number from the AL_PA lookup table that
appears. For more information, see
“Table C-5. Arbitrated Loop Node number to AL_PA