Chapter 6: Using Visual Manager
Figure 6-19. Overrides Settings screen
To finalize any changes for the override settings, select the Submit button beneath the
override menu options.
Alternate Initiator ID can be assigned an Initiator ID, which is the ID for a second SCSI
device that can request operations from other SCSI devices, or targets. This ID should be a
unique ID on the bus. The default setting is OFF.
Internal Termination enables/disables internal termination of the selected SCSI bus. The
default setting for this option is enabled, which allows the VT5900-SA to internally terminate
a SCSI connection. Setting this option to disabled allows the SCSI Bus, not the VT5900-SA,
to handle SCSI terminations.
Note: Normally, override settings should not be changed except when directed to do so by
an authorized HP technician.