WAN Subsystem Configuration and Management Manual

Configuration Quick Start
WAN Subsystem Configuration and Management Manual522463-011
1-3
HP Manufacturing Naming Conventions (G06.26 and
Earlier RVUs)
HP Manufacturing Naming Conventions
(G06.26 and Earlier RVUs)
HP manufacturing uses a naming convention for processes and devices that relates
logical names to the physical location of devices.
The WAN manager process automatically configures the WANBoot, TFTP server, and
the SNMP trap multiplexer processes.
m
is an alphabetic value (A-Z) assigned automatically by the WAN manager process.
n
is an alphanumeric value (A-Z or 0-9) assigned automatically by the WAN manager
process.
Note. The SNMP trap multiplexer does not require a corresponding SNMP agent process. The
WAN manager process does not configure SNMPTMUX with an SNMP agent process.
$ZWBmn, $ZTFmn, and $ZTXmn are reserved process names.
Table 1-1. Naming Conventions for WAN Subsystem, Related Processes, and
LAN Adapters (G06.26 and Earlier RVUs)
Process or Device Type Convention Example
WAN manager process Must be $ZZWAN $ZZWAN
TFTP server process $ZTFmn $ZTFAC
WANBoot process $ZWBmn $ZWBAC
NonStop TCP/IP process $ZBcabid-portid $ZB018
Logical interface (LIF) Lcabid-portid L018
SNMP agent process $ZTMXA, $ZTMXB, and so on $ZTMXA
SNMP trap multiplexer process $ZTXmn $ZTXAC
E4SA, FESA, or GESA Ecabid-slot E0153
G4SA
See G4SA Naming Conventions (G06.24, G06.25, and
G06.26 RVUs) on page 1-5
SWAN or SWAN 2 concentrator Sconcnum S01
Note. The WAN manager process does not impose any restrictions on adding a
PROCESS using the convention name, but use these names to add WAN processes to