Web ViewPoint User Guide, Version 5.14
Web ViewPoint User Guide Version 5.14 - 528226-014  109 
Click on the Submit button once your selections are made. A new Token Analyzer Analysis  window  will be 
displayed based on your defined settings. These settings are also kept in a cookie on your PC, and applied again 
the next time you open the Token Analyzer, Setting Window.  
[Back to TOC] 
4.2.3.2 TOKEN ANALYZER ANALYSIS 
The Analysis Window displays a set of past EMS Event messages based on your settings in Token Analyzer Settings 
Window. This new Window contains a list of all Tokens for the selected messages. Navigational controls give you 
the option of which Events and tokens should be displayed, and in what format.  Please see, 
Token Analyzer 
Analysis for more details. 
4.2.3.3 FILTER CRITERIA PASS OR FAIL INTERPRETATION 
In Web ViewPoint Lite events live, query or token analyzer settings, users can set the filter criteria to be PASS or 
FAIL. The default value set is PASS. The Pass/Fail option applies only to the Owner/Subsystem/Event number 
combination. The PASS or FAIL criteria is based on the selection made within the section shown in the figure 
below: 
String matching is always “positive” (must match). Even if FAIL is selected, the string criterion will be matched and 
displayed in the results.  
Please see the example below to know how the pass or fail settings is interpreted. 
Consider the following 4 scenarios in events live settings: 
1.  Selected Owner-Subsystem-Event is none. From time is 06/07/13  12:50:00 pm. The filter is PASS. The 
result we get is 100 events. 
2.  Selected Owner-Subsystem-Event is TANDEM.ASAP.512. From time is 06/07/13 12:50:00 pm. The filter is 
set to PASS. The result we get is 20 events which contain 15 events with text ‘AAA’ and 5 events with 
text ‘BBB’. 
3.  Selected Owner-Subsystem-Event is TANDEM.ASAP.512. From time is 06/07/13 12:50:00 pm. The filter is 
set to PASS. The String is set to ‘BBB’. The result we get is 5 events. 
4.  Selected Owner-Subsystem-Event is TANDEM.ASAP.512. From time is 06/07/13 12:50:00 pm. The filter is 
set to FAIL. The result we expect to get is the remaining 15(Events with event number set to 512 minus 
events that match string ‘BBB’ which is 20 - 5) events but we get all events that do not match the criteria 
TANDEM.ASAP.512 but matches the string ‘BBB’.  










