X25AM Configuration and Management Manual

SCF Commands for the X25AM Subsystem
X25AM Configuration and Management Manual523424-004
4-36
Display for the STATS LINE Command
ALL specifies that the named object and the subordinate objects are affected. If
you omit subtype, ALL is assumed.
Display for the STATS LINE Command
The format of the display for the STATS LINE command is:
The statistics are described below in the order in which they appear on the screen. The
information listed in the statistics display apply only after the last RESET and/or system
restart.
Resettime
is the date and time the last reset operation was performed.
Sampletime
is the current date and time.
Line Quality
shows the value SCF uses to check the quality of the transmission. This value is a
percentage and is calculated as a function of the SCF THRESHOLD value.
X25AM STATS Line $X25P1
Resettime 7:04:59.023 10/12/99 Sampletime 8:07:22.034 10/14/99
Line Quality 100 Modem Error 0 Modem Overrun 0
[ Packet Level Information ]
Data Call Clear Reset Rstrt Intrp Diag RR RNR REJ
Send 0 0 0 0 0 0 0 0 0 0
Rcvd 0 0 0 0 0 0 0 0 0 0
[ Confirmation Packets ]
Send 0 0 0 0 0
Rcvd 0 0 0 0 0
Total Sent 0 Total Rcvd 0 Invalids Rcvd 0 Discarded 0
[ Frame Level Information ]
For CLIP Subsystem:
I^P I^NOP RR RNR REJ SREJ SABM DISC FRMR UA DM
Send 0 0 0 0 0 0 0 0 0 0 0
Rcvd 0 0 0 0 0 0 0 0 0 0 0
[ CLIP Errors ] [ DRIVER info ]
FCS 0 Modem 0 Length 0 Overruns 0 BCC Errs 0 Frames 0
T1 0 Nobuf 0 Addrs 0 Rvc Abrt 0 No Buffs 0 Errors 0
[ Buffer Pool Information in pages ]
Size 510 In use 4 High Water 5 Failures 0
Note. For statistical information about the CLIP, refer to the statistics listed in the display.